LT665-1550 Beam Profiling Camera

Updated:2025-03-13

Views:2072

  • Brand: OPHIR
  • Model: LT665-1550
  • Description: The LT665-1550 camera accurately captures and analyzes wavelengths from 1440nm - 1605nm. It features a compact design, wide dynamic range, unparalleled signal to noise ratio, and a 1" format that make
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

LT665-1550 Beam analysis camera features

  1. 12.5mm x 10.0mm active area with an effective 60μm pixel pitch

  2. Adjustable Gain levels and programmable electronic shutter

  3. BeamGage Standard or Professional software included

  4. USB 3.0 Phosphor Coated Large Format Silicon CCD High Resolution Camera with BeamGage

LT665-1550 Beam analysis camera drawings

LT665-1550 Beam analysis camera specifications

Wavelengths 1440-1605nm
Beam Sizes 600μm - 9.8mm
Interface USB 3.0
Sensor Type Phosphor-Coated Silicon CCD
Compatible Light Sources CW, Pulsed
Active Area 12.5mm x 10.0mm
Elements 2752 x 2192
Effective Pixel Pitch 50μm
Dynamic Range ~30 dB
Frame Rate at Full Resolution 27 fps
Compliance CE, UKCA, China RoHS

LT665-1550 Beam Analysis camera FAQ

Camera Image Quality – We frequently get asked about image quality as it relates to dead or bad pixels in the imager array. These questions most generally fall into one or more of these categories. Will my camera have any bad pixels? Do bad pixels affect my laser profile measurement? Can bad pixels be corrected? If I have some bad pixels what can I do about it? Will my camera performance change over time? All and more of these concerns are explained in our Camera Defects Policy document.

Camera Defects Policy

Ophir-Spiricon, LLC (OSL) is a supplier of laser beam analysis tools that employ commercial-industrial solid-state cameras. OSL attempts to supply cameras with as few pixel defects as possible. OSL tests for and corrects defective pixels that may have an adverse effect when used for its intended purpose. OSL does not guarantee that a supplied camera will be defect free, or that they will remain defect free during its normal lifetime and under normal use.

It is not uncommon for modern megapixel camera imagers to develop point defects as they age, even when not subjected to abuse. Imagers without windows often experience point defects at rates typically greater than imagers with their cover glass left in place. Point defects can also appear more frequently when operating at higher rather than lower ambient temperatures, and higher relative humidity. Such defects can occur even when the camera is in storage and not being used.

Cameras supplied by OSL will be certified for use in laser beam analyzer applications. When defects occur, the ability to make certain measurements under certain conditions may be compromised. However, depending upon the nature of the defect, most measurement can still be performed without loss of accuracy. In some instances the effects of defects can be eliminated or significantly reduced by adjusting the manner in which the camera is being employed.

Ophir-Spiricon, LLC offers a camera recertification service. This service can help to extend the useful life of your camera and correct some point defects that may show up over time. This service can not correct cameras with serious laser damage or imager degradation. Whenever possible OSL will restore the camera to our "as new" level of certification; and if not possible, we will indicate to the user how to avoid areas of the imager that may not perform to "as new" standards.

Defects, Solutions and Workarounds

The following list contains examples of typical camera point defects that may occur over time, and suggested methods of compensating for them if they are troublesome:

Defect type Description of the Problem Recommended Solution
See Note 1 below
Bright Pixel Pixels with this defect will indicate being illuminated even when no signal is present. These are the most troublesome when attempting to make accurate peak fluence and peak fluence location measurements because they represent a false signal. Most other measurements are not adversely affected by this type of defect. This type of defect is screened for during our regular camera inspection process. All pixels that exceed a set limit are corrected, if possible, before the camera ships. See Note 1 below. Our QA department will often reject cameras if the pixel can not be corrected and it exceeds our acceptance criteria.
  1. Ultracal/baseline correction will subtract out the defective pixel.
  2. Reposition the camera to remove the defective pixel from the measurement region and employ a manual aperture to isolate the pixel from the area of interest.
  3. Return the camera to OSL to have the bad pixel corrected and the camera re-certified.
Twinkling Pixel This is an intermittent version of the Bright Pixel defect. These often appear as the camera warms up. May disappear if the camera is run in cooler environments. Usually predicts a pixel that will soon be a permanently bright pixel defect.


These are the hardest to detect and as such may get past our camera inspection process.

Same as above.


If returned to OSL to be corrected please send a full frame data file showing the pixel as it is malfunctioning. This will aid in our ability to find and fix it.

Dark Pixel Dark pixels have low responses compared to the amount of illumination that they receive. Isolated instances of these types of defects do not pose a serious beam analysis problem and they are generally not in need of correcting. This type of defect will not significantly impact a beam measurement result unless the beam is very very small and the defect falls inside of the beam profile. Reposition the camera to remove the defective pixel from the measurement region.
Dead Pixel Dead pixels have no response at all and may output a raw pixel value of zero (0) counts. This type of defect is screened for during our regular camera inspection process. All pixels that exceed a set limit are corrected, if possible, before the camera ships. This type of pixel may create a warning message when performing Ultracal operations. Ignore the warning and proceed as in the Dark Pixel case described above.
Dark Clusters These dimmer than normal clusters involving about a dozen or fewer pixels are often caused by dust particles and can usually be removed by cleaning of the imager. Sometimes these can be very difficult to impossible to remove. In the latter case they are may be melted into imager


If this is the result of laser damage then imager replacement is the only solution.

These usually do not cause serious measurement problems and can be treated with the Dark Pixel workaround described above. They can sometimes be dislodged with very gentle puffs of dry air. If you return a camera to be re-certified we have a few special methods for cleaning these, but success is not 100% guaranteed.
Regions of non-uniform response When large areas of an imager yield reduced signal levels this usually indicates laser damage. Long term exposure to ultraviolet radiation or overexposure to high laser power or peak energies are common causes. This type of degradation is not repairable and either the camera or the camera imager must be replaced.
How come I can't use the Cameras Region Of Interest (ROI) Feature in my SP503U or SP620U Camera?

The initial release of the SP503U and SP620U cameras did not have the ROI feature enabled.

Why is an anti-reflection coated window required with the Pyrocam III?

The Pyrocam III needs a window for protection against foreign objects entering the camera, and destroying the crystal. This could happen by someone poking a brush or Q-tip to clean off lint, etc. The window also protects the sensor from the effects of humidity. The window must have anti-reflection coating, or the two surfaces of the window will create interference fringes from a collimated light source which show up on the sensor as ripples in the beam. With anti-reflection coating the reflections, and thus the interference fringes, are minimized, and the sensor sees only the beam energy.

WeChat

Customer Service QQ

Customer Hotline:

0l0-52867771
l3811111452
l7896OO5796

Technical Supports

l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 久久国产精品99久久久久久口爆 | 在线视频97 | 欧美第一黄网免费网站 | 免费在线观看av | 婷婷久久综合九色综合 | 三攻一受h啪肉np文 少妇又紧又色 | 久久电影网午夜鲁丝片免费 | 2018自拍偷拍视频 | 国产精品自拍av | 欧美 亚洲 中文 国产 综合 | 国产成人a人亚洲精v品无码 | 欧美日比视频 | 成人性生交大片免费看4 | 久久午夜免费观看 | 同性男男黄g片免费网站 | 欧美日韩视频无码一区二区三 | 亚洲成人高清在线 | 亚洲中文字幕精品一区二区三区 | 黄av在线| 97xxxxx | 国产无限制自拍 | 国产美女裸身网站免费观看视频 | 精品麻豆 | 一级特级片 | 国产成人精品aa毛片 | 亚洲综合一区在线 | 国产又粗又硬又猛的毛片视频 | 一级片av | 欧美精品三级 | 阿v天堂在线观看 | 久久久久久无码精品人妻a片软件 | 强行18分钟处破痛哭av | 人妻内射一区二区在线视频 | av在线亚洲男人的天堂 | 国产综合婷婷 | 狠狠噜天天噜日日噜国语 | 亚洲色成人一区二区三区小说 | 中文字幕乱码熟妇五十中出色欲 | 久草在线资源福利 | 波多野结衣一区二区三区高清 | 久久婷婷综合色 | 婷婷精品视频 | 日本高清在线一区 | 国内自拍一二三四2021 | 人人妻一区二区三区 | 久操久热 | 欧美性色黄大片a级毛片视频 | 小猪佩奇第七季中文免费版 | 国产一区二区三区黄 | 自慰小少妇毛又多又黑流白浆 | 久国产精品 | 日韩视频一区二区 | a级片在线免费观看 | www.在线观看麻豆 | 日本亚洲色大成网站www久久 | 国产真实偷伦视频 | 亚洲另类激情专区小说图片 | 嫩草视频在线观看免费 | 男人午夜影院 | 国产一区二区三区视频在线 | 无码日韩精品一区二区三区免费 | 无码专区亚洲综合另类 | 日韩免费特黄一二三区 | 99视频精品 | 亚洲五十路 | 精品国产乱码91久久久久久网站 | 亚洲呦女专区 | 国产精品久久人妻无码 | 日韩一级黄色片 | 成人开心网 | aa性欧美老妇人牲交免费 | 2023av在线| 亚洲高清揄拍自拍 | 国产精品久久久久久久久借妻 | 无码中文精品视视在线观看 | 国内少妇情人精品av | 一个人在线观看免费中文www | 一级黄色毛片子 | 国产欧美综合在线观看第十页 | 91蜜桃传媒精品久久久一区二区 | 国产又粗又猛又爽又黄的视频小说 | 天堂资源在线播放 | 国产熟睡乱子伦视频在线观看 | 中文字幕天堂中文 | 怡红院av一区二区三区 | 91av国产精品 | 精品国产户外野外 | 一区二区三区播放 | 777亚洲精品乱码久久久久久 | 麻豆av在线| 国产在线精品一区二区 | 国产一级 黄 片 | 国产亚洲人成网站在线观看 | 国产高清一区二区三区视频 | 日韩欧美在线综合网另类 | 中国真实的国产乱xxxx | 日本一级特黄高潮 | 亚洲精品国偷拍自产在线麻豆 | 五月深爱 |