TCOMSYS01 Hot Cube Thermal comfort measuring system: User's Manual Datasheet

Introduction

TCOMSYS01 was originally designed to study the effect of radiation sources on human comfort. Equipped with heat flux sensors that measure in 5 directions and a humidity and temperature probe, it offers a good picture of energy gains and losses from all sides to a metal body that thermally resembles the human body; the TCOM01 sensor is in essence a miniature thermal mannequin.

The TCOMSYS01 system employs dedicated sensors and electronics, measuring thermal comfort according to the new Hot Cube method. The high accuracy of the MCU (Measurement and Control Unit) ensures that TCOMSYS01 will still measure down to very low heat fluxes. The MCU has a robust aluminum housing. The system generates a measurement file, including a time-stamp. The measurement data are stored in the MCU and are later downloaded to a PC. The user is responsible for data analysis.

How to employ TCOMSYS01

The primary source of information from TCOMSYS01 simply is the power [W] required to keep the TC0M01 sensor at a constant temperature; a very direct measure of human comfort. This power may be compared to the power required at 20 °C ambient air temperature, no convection (zero wind speed), and no radiation. Power consumption will immediately show if there is a situation of overheating or heat stress or a situation of overcooling or cold stress.

The second direct information supplied by the heat flux sensors of TCOMSYS01 is the heat loss or gain [W/m2] as a function of direction. If radiative sources are dominant, TCOMSYS01 will measure radiative asymmetry.

To study the exact effect of radiative sources, in many cases a simple experiment, like switching a radiation source [on] and [off] or shielding a radiation source, can be used to distinguish between convective and radiative heat transport.

Far-infrared radiation sources may be studied by temporary shielding with a silicon wafer. Silicon has around 50 % transmission. Radiation from the sun or lamps may be quantified by shading and unshading.

To study the insulating effect of clothing, TCOM01 may be insulated using the same fabrics.

A web browser may be used for real-time measurement review, data collection, and for changing control settings such as TCOM01 body temperature.

History

Already in 1929 the Eupatheoscope (from Greek “wellbeing–emotion–examination”) was designed by A.F. Dufton to quantify the condition in a room from the point of view of comfort. It consists of a blackened cylinder that is controlled to maintain a temperature of 23 °C. The power used is interpreted in terms of equivalent temperatures.

In 1990 the company Bruel & Kjear carried a thermal comfort meter (model 1212), based on the same principle, in addition to processing Fangers equation.

Both models involved only an integrated power measurement. The new Hot Cube method improves on this by incorporating omnidirectional heat flux measurements.

What makes TCOMSYS01 different?

The main contributors to thermal comfort are air temperature, airspeed, radiant temperature, and humidity. Apart from this, there are personal contributors such as metabolic rate and insulation by clothing.

Many studies use Fanger’s thermal comfort equation as applied in EN ISO 7730: Moderate Thermal Environments – Determination of the PMV and PPD indices and specification of the condition for thermal comfort. Another approach utilizes a globe temperature measurement: EN ISO 27243: Hot environments. Estimation of the heat stress on working man, based on the WBGT Index (Wet Bulb Globe Temperature).

These methods are quite indirect in particular when determining the heat flow from airspeed and radiation.

  • offers heat flux measurements. This approach is a lot more direct than the indirect estimate from airspeed and radiation.
  • TCOMSYS01 offers directional information.
  • TCOMSYS01 works at a realistic skin temperature of 33 °C (user adjustable).
  • Rated operating conditions

    TCOMSYS01 is designed to work between +10 and +25 °C. In its standard configuration, uninsulated and stabilized at 33 °C, it is rated for operation in indoor conditions including significant radiative heating.

    It will stabilize at 33 °C under approximately one of the following conditions:

  • air speeds < 5 m/s
  • irradiance < 400 W/m2
  • ambient air temperature > 5 °C
  • Under other conditions, the sensor may not be able to stabilize its body temperature due to overheating (indicating overheating or heat stress) or shortage of electrical power (indication of overcooling or cold stress). Powered using a low voltage, TCOMSYS01 is safe to use.

    TCOMSYS01 may be used for short-term outdoor experiments in the order of weeks. Under long-term exposure to solar radiation, the black heat flux sensor coating may become more reflective.

    User interface: MCU is a web server

    he MCU serves as a web server and can be connected to any local area network. No more downloading USB drivers and special interface software! Alternatively, it offers an “Ethernet over USB” or virtual Ethernet link, where you connect to the MCU using a USB cable. If you type into your web browser the MCU’s IP address (192.168.66.1 by default), you have access to the user interface.

    Ordering the TCOM01 sensor only

    The sensor TCOM01 is also available as a “sensor only”; The configuration then includes the mannequin with 5 x heat flux, 1 x temperature, 1 x heater, 2 x cable, 2 x chassis connector, and 1 x tripod. The user then must combine it with his or her own measurement and control unit.

    Suggested Use

  • surveys of human thermal comfort
  • studies of the effect of radiating sources
  • workplace investigations
  • car passenger comfort testing
  • educational purposes, illustrating heat transfer
  • bio-meteorology
  • microclimate studies
  • wind-chill analysis
  • analysis of fabric insulation
  • Areas of Application

  • Building physics / insulation, thermal comfort, and energy budget measurement
  • TCOMSYS01 Hot Cube Thermal comfort measuring system Specifications:

    Measurand heating power for stabilization, heat flux (5x), ambient air temperature, relative humidity, TCOM01 body temperature
    TCOMSYS01 specifications :
    TCOM01 temperature setting 33 °C (user adjustable)
    Included cable 2 x cable with 2 connectors (1.5 m)
    Standard rated operating temperature range +10 to +25 °C
    Limiting temperature range – 25 to +50 °C
    Required data analysis To be performed by the user
    Data display in web browser
    Start up interval < 10 min
    TCOM01 specifications :
    Weight 1.12 kg
    Temperature sensor 10 kΩ thermistor
    IP protection class IP65
    Mounting tripod with ? inch -20 UNC screw; a Manfrotto Pixi EVO 2-section tripod is included
    MCU specifications :
    User interface on MCU as a web page
    Connection via LAN or “Ethernet over USB”
    Voltage measurement accuracy 4 x 10-6 V (0.8 W/m2)
    Rated power supply voltage 10 to 16 VDC
    Adapter power supply 100 – 240 VAC, 50/60 Hz
    Rated operating temperature range MCU – 25 to +50 °C
    Data storage capacity 2GB; > 1 year of data
    Options 2GB; > TCOM01 sensor only extended rated operating conditions; temperature, irradiance, wind speed

    WeChat

    Customer Service QQ

    Customer Hotline:

    0l0-52867771
    l3811111452
    l7896OO5796

    Technical Supports

    l7896OO5796
    info@dorgean.com
    主站蜘蛛池模板: 免费人成网站 | 精品人妻潮喷久久久又裸又黄 | 欧美极品一区二区三区 | 熟妇乱子作爱视频大陆 | 亚洲热无码av一区二区东京热av | 亚洲日韩精品a∨片无码加勒比 | 成人免费看片在线观看 | 国产成人精品手机在线观看 | 亚洲精品久久无码av片 | 国产青青草视频 | 日韩欧美一二三 | 射精区-区区三区 | 性一交一乱一色一视频麻豆 | zzijzzij亚洲日本成熟少妇 | 蜜桃视频一区二区在线观看 | av片免费在线播放 | 国产欧美在线一区 | av无码电影一区二区三区 | 一二三四在线观看免费视频 | 日韩毛片儿 | 国产91热爆ts人妖月奴 | 中文不卡在线 | 人妻精品动漫h无码网站 | 国产精品亚亚洲欧关中字幕 | 俄罗斯毛片基地 | 中国洗澡偷拍在线播放 | 色视频在线观看 | 国产精品制服丝袜 | 国产色欲av一区二区三区 | 原神污文全文肉高h | 丰满熟妇人妻av无码区 | 国产成人麻豆精品午夜在线 | 成av人片一区二区三区久久 | 91视| 亚洲欧美精品在线 | 国产三级影院 | 蜜桃无码一区二区三区 | 自拍偷拍21p | 天天爽天天干 | 一级淫片免费 | 国产成人午夜福利高清在线观看 | 久久99久久99精品免视看看 | 国产亚洲精品久久久优势 | 国产一区二区三区乱码 | 久久aaaa片一区二区 | 久久久亚洲欧洲日产无码av | 亚洲成av人片在线观看无码 | 少妇一级淫片免费放播放 | 奇米777四色在线精品 | 天堂tv亚洲tv无码tv | 东京道一本热中文字幕 | 国产精品女主播主要上线 | 国产精品亚洲а∨怡红院 | 精品欧美日韩 | 无码人妻久久一区二区三区免费丨 | 精品国产一区二区三区蜜殿 | 超碰超在线 | 成人av无码国产在线一区 | 欧美性生交xxxxx久久久 | 午夜福利小视频400 日本三级带日本三级带66 | 国产又黄又爽又色的免费视频白丝 | 亚洲国产综合无码一区二区bt下 | 久久久久久久久久久久久久久 | 国产一级特黄视频 | 自拍偷拍综合 | 欧美jizzhd精品欧美喷水 | 欧美成人国产va精品日本一级 | av图区 | 亚洲成人1区 | 特黄特色大片免费观看播放器 | 亚洲国产精品久久久久秋霞影院 | 亚洲乱码国产乱码精品精98 | 亚洲一区综合图区 | 国产乱女婬av麻豆国产 | 欧美国产国产综合视频 | 性夜影院午夜看片 | 午夜啪啪网站 | 亚洲成人看片 | 鲁丝久久久精品av论理电影网 | 欧美天堂网站 | 亚洲精品无码鲁网中文电影 | 国产欧美一级二级三级在线视频 | 中文字幕日本免费毛片全过程 | 欧美高潮视频 | 久久影视久久午夜 | 欧美丰满熟妇乱xxxxx图片 | 亚洲国产成人久久一区 | 五月丁香拍拍激情综合 | 人人曰人人做人人 | 久久久久久夜精品精品免费啦 | 国产人妻精品无码av在线 | 日韩国产一区二区三区四区 | 激情亚洲一区国产精品 | 国产午夜精品av一区二区 | 无码日韩人妻av一区二区三区 | 羞羞视频靠逼视频大全 | 久久久久人妻精品一区三寸蜜桃 | 欧美性猛交xxxx乱大交密桃 | 综合三区后入内射国产馆 |